BIO-SPARGE SMB-320 (415 volt supply) The BIO-SPARGE SMB-320 is our largest system and widely used for mills, abattoirs for biosecurity both in the UK and overseas. The Bio-Sparge SMB is a Farm Entrance Security System designed to automatically spray vehicles entering or exiting where the entrance and exit roadway need to be controlled separately with …
SERVICES REQUIRED
ELECTRICAL
380-415v, 50Hz, 3P + N + E, 16A, Three Phase Bio-Sparge Units
A qualified electrician should undertake the electrical installation. All electrical components are CE Marked and the Control Cabinet wired to EN60204-1.
Note: We recommend that an RCD is fitted to the Electrical supply to the Bio-Sparge SMB. General use: 30mA 20 millisecond, Equine, Racehorse installations: 30mA 5 millisecond.
WATER
We recommend that a tap, or isolation valve should be installed in the water supply to the Bio-Sparge Cabinet, to allow the water supply to be turned off for maintenance of the Bio- Sparge SMB.
Clean Mains water, or a Borehole water supply, minimum pressure 2 bar (29 PSI) maximum pressure 7 bar (100 PSI).
If the water supply is not clean then an inline filter should be fitted to ensure that only good quality water is supplied to the Bio-Sparge SMB.
Note: The Bio-Sparge SMB incorporates back flow protection (WRAS classification Type A Air Gap with Circular Overflow). However some Water Authorities may consider that the fitment of a reduced pressure zone valve, or other verifiable backflow prevention device for protection against backflow in fluid category 4 or 5 is necessary. If in doubt contact your local Water Authority or a qualified ACP (Institute of Plumbing & Heating Engineers Approved Contractor Person).
CHEMICAL / DETERGENT
It is recommended that a biodegradable PH neutral Chemical / Disinfectant is used with the Bio-Sparge SMB.
Consult with your chemical supplier and ensure that the chemicals used comply with all regulations and local bylaws.
CONCRETE BASE
The system needs to be mounted on a concrete base with all of its counter parts (sensor posts, spray bars, main unit etc).